Additional information
Manufacturer | |
---|---|
Brand | |
Model | |
Country of Origin | |
Year of Introduction | |
If discontinued , the Year Discontinued | |
Suspended In | |
Aerodynamically designed Shadow less surgical light based on LED microprocessor control technology. | |
Light Intensity at 1meter disctance (LUX) | |
Light field diameter d10 at a distance of 1m | |
No. of LED's | |
Whether each LED be replaceable individually | |
Dimming Range | |
Colour Temp (Kelvin) | |
Colour Temp (Kelvin) Range | |
The color temperature of tight should remain constant in all he ldimming levels and not subject to unwanted changes | |
Colour Rendering Index Rₐ | |
Red rendering index R9 | |
Light Patch Diameter at a distance of 1m (in cm) | |
Depth of illumination | |
Depth of illumination at 20% without additional focussing (L1+L2) | |
Depth of Illumination at 60% without refocusing (cm) L1+L2 | |
Temperature increase at Operating site | |
Is it possible to control the intensity, color temperature and field size with a cordless remote control handset, so as not to disturb the sterile area. | |
User selectable intensity variation with digital display from 25% to 100% at least in 20 different levels | |
Life span of the LED's | |
Should have stable illumination throughout the life period of the light. | |
Electronic light intensity & Field Size control at the lamp head/arm | |
Detachable & Autoclavable Handle (Should be able to sterilize any number of times) | |
Tourbulance Intensity of the Light Head | |
Wall Keypad for Light controls | |
Power input: | |
Power Consumption (W) | |
Electronic Voltage corrector/stabilizer of appropriate ratings meeting BIS Standards/Specifications.( Input 160- 260 V and output 220-240 V and 50 Hz) | |
FDA Certificate | |
CE Certificate | |
STQC Certificate | |
IEC 60601-1:2012 Medical electrical equipment - Part 1: General requirements for basic safety and essential performance | |
IEC-60601-1-2 :latest edition for Electro Magnetic Compliance. | |
or should comply with 89/366/EEC; EMC-directive as amended | |
Certified to be compliant with IEC 60601- 2-41: Particular requirements for the safety of Operation Theatre Light or equivalent if applicable | |
Built-In Provision for Detachable Camera (Should be 1080 pixel camera) | |
The output of the camera shall be taken out and connected to the monitor / TV provided by the user institution (Maximum distance: 100meters) | |
Recording Device (DVD writer,Memory | |
Provision for third arm with monitor stand with cables for video and power - Optional. | |
The light head should be so constructed as to provide optimum conditions for laminar flow. | |
The light domes should have an endo function controlled from a single switch on the control panel, so as to have bare minimum lighting in the OT to facilitate certain procedures. | |
Dome body should be of single piece and should have provision for air circulation. | |
Size of the light dome | |
Provision for camera in one of the domes | |
Surgical light consisting of: Central axis, horizontal extension arm, height adjustable spring arm, vertical and horizontal bow and the one-point suspended lighthead | |
Suspension system: Main light on lowermost axis position. | |
The maximum movement angle of the spring arm. | |
The maximum movement range of the horizontal arm & spring arm | |
The thickness of the light head | |
Operating range: 2000 mm or more | |
All arms to be freely rotatable (without stops) at all vertical joints | |
Is it possible to integrate the Light control with the central control console of the operation theater if need arises in future | |
The unit shall be capable of being stored continuously in ambient temperature of 0 - 50 deg C and relative humidity of 15-90% | |
The unit shall be capable of operating continuously in ambient temperature of 10 -40deg C and relative humidity of 15- 90% | |
The light should be useful in laparoscopic surgery with all the options. | |
Ambient (Endoscopy) Illumination: 12,800 Lux | |
Radiant energy (average): ≤3.6 mW/m2*Lux | |
Shadow dilution with tube | |
Optional facility of AICS function | |
Shadow dilution with one mask | |
Shadow dilution with tube and one mask | |
Shadow dilution with two masks | |
Shadow dilution with tube and two masks | |
Protection against harmful ingress of water or particulate matter |
Reviews
There are no reviews yet.