Manufacturer |
Varian Medical Systems
|
Brand |
Varian
|
Model |
Clinac 2100 C / 2100 CD
|
Year of Introduction |
1987
|
If discontinued , the Year Discontinued |
2007
|
Single Energy |
–
|
Dual Energy |
Dual
|
Energy - Photon Configuration MV |
6 & 10/15/18 MV
|
Energy - Photon Configuration - 4 mv |
–
|
Energy - Photon Configuration - 6 mv |
–
|
Energy - Photon Configuration - 10 mv |
–
|
Energy - Photon Configuration - 15 mv |
–
|
Energy - Photon Configuration - 18 mv |
–
|
Energy - Electron |
Yes
|
Energy - Electron Configuration - 6 MEV |
–
|
Energy - Electron Configuration - 9 MEV |
–
|
Energy - Electron Configuration -12 MEV |
–
|
Energy - Electron Configuration -15 MEV |
–
|
BEAM Energy Consumption / Generator / Power Source |
Klystron
|
Multi Leaf Collimator (MLC) - No of Leaves |
80 MLC / 120 MLC
|
Multi Leaf Collimator (MLC) - No of Leaves 80 MLC |
–
|
Multi Leaf Collimator (MLC) -No of Leaves 120 MLC |
–
|
Multi Leaf Collimator (MLC) - No of Leaves 120 HDMLC |
–
|
Multi Leaf Collimator (MLC) - No of Leaves 160 Agility MLC |
–
|
Multi Leaf Collimator (MLC) - No of Leaves Dual Layer |
–
|
Multi Leaf Collimator (MLC) - No of Leaves optional |
–
|
Multi Leaf Collimator (MLC) - Thickness of Leaves |
Central 20cm of field -5 mm Outer 20 cm of field – 10 mm
|
Multi Leaf Collimator (MLC) - Thickness of Leaves - 5 mm |
Central 20cm of field -5 mm
|
Multi Leaf Collimator (MLC) - Thickness of Leaves - 10 mm |
Outer 20 cm of field – 10 mm
|
Multi Leaf Collimator (MLC) - Field Size |
40 x 40 cm
|
Portal Imager (EPID) |
LC250, as500, aS1000 (Optional)
|
Treatment Delivery |
3D, IMRT, SRS/SBRT (Optional)
|
Treatment Delivery - 3D |
–
|
Treatment Delivery - IMRT (Intensity Modulated Radiation Therapy) |
–
|
Treatment Delivery - VMAT |
Only with OBI
|
Treatment Delivery - Rapid Arc |
–
|
Treatment Delivery - SRS (Steriotactic Radio Surgery) |
Optional Cones or mMLC
|
Treatment Delivery - SBRT (Steriotactic Body Radio Surgery) |
–
|
Treatment Delivery - SRT (Steriotactic Radiation Therapy) |
–
|
Treatment Delivery - SABR (Steriotactic Ablative Radio Therapy) |
–
|
Treatment Delivery - IGRT (Image Guided Radiation Therapy) |
–
|
KV Imaging for IGRT |
OBI (Optional)
|
IGRT Field of View (FOV) |
–
|
Cone Beam CT (CBCT) |
Only with OBI
|
Cone Beam CT (CBCT) - 3D CBCT |
–
|
Cone Beam CT (CBCT) - 4D CBCT |
–
|
CBCT FOV |
–
|
Cones - with SRS Planning |
–
|
Silhouette Option for small size rooms Available |
Yes
|
3 D Conformal Radio Therapy |
–
|
3 D KV Imaging - XVI |
–
|
FFF 6 Mv |
–
|
FFF10 Mv |
–
|
Is the MLC HD ? |
–
|
Field Coverage |
–
|
Small Field Delivery for Precise applications e.g. Brain |
–
|
Gating Software and Hardware included in Price |
–
|
Treatment Couch |
–
|
4 D Couch |
–
|
6 D Couch |
Yes
|
Laser Aimer light - Green |
–
|
Laser Aimer light - Red |
–
|
Immobilisation included in Price ? |
–
|
Standard Immobilization |
–
|
UPS required KVA |
–
|
UPS Included as standard Accessories ? |
–
|
Tonnage of Chiller |
–
|
Chiller Included as standard Accessories ? |
–
|
Market Demand |
–
|
Other Variants |
–
|
Pros |
Similar to 21 EX & iX
|
Cons |
Similar to 21 EX & iX
|
Reviews
There are no reviews yet.